Data Center Equipment Prefabricated Steel Building 10 kN Floor Load Sealed Envelope

Ringkasan Produk

An equipment building is a structure designed around concentrated loads. A row of server racks or a switchgear line puts 10 kN per square metre on the slab, and a single battery room can exceed that in one small area. This building uses a 8 m by 8 m column grid with a slab designed for 10 kN per ...

Atribut Kustom Produk

Beban lantai::
10 kN per meter persegi umum, 20 kN di zona peralatan
Kisi::
8 m kali 8 m dengan balok sekunder 6 m
Amplop::
Panel berinsulasi 100 mm, sambungan tertutup, penghalang uap
Beban Atap::
1,5 kN per meter persegi untuk pembangkit listrik ditambah 0,5 kN layanan
Pemisahan api::
dinding ruang baterai 120 menit
penyelesaian lantai::
Epoksi tersegel, tahan asam di area baterai
Pendinginan::
Unit yang dipasang di atap pada rangka terisolasi dengan rute pengangkatan
Entri listrik::
Penetrasi yang telah dibentuk sebelumnya dengan kerah penghenti api
Struktur::
Rangka Q355B, baja sekunder galvanis
Menyoroti::

data center steel building

,

equipment building structure

,

sealed steel envelope building

Properti Dasar

Tempat asal:
Tiongkok
Nama merek:
KXD Steel Structure
Sertifikasi:
ISO 9001, CE, EN 1090
Nomor model:
KXD-PB-DC10

Properti Perdagangan

Kuantitas min Order:
300 meter persegi
Harga:
USD 42 - 75 per square meter
Kemasan rincian:
Bundel telanjang dalam wadah, tepi panel ditumpuk, aksesori dikemas berdasarkan urutan pemasangan
Waktu pengiriman:
25 - 40 hari kerja setelah persetujuan gambar
Syarat-syarat pembayaran:
T/T deposit 30%, 70% sebelum pengiriman; L/C pada pandangan
Menyediakan kemampuan:
8000 ton per bulan

Deskripsi Produk

An equipment building is a structure designed around concentrated loads. A row of server racks or a switchgear line puts 10 kN per square metre on the slab, and a single battery room can exceed that in one small area. This building uses a 8 m by 8 m column grid with a slab designed for 10 kN per square metre general load and 20 kN in designated equipment zones, a sealed envelope with controlled humidity, and roof structure sized for the cooling units and cable trays that will