logo
Quality Energy Efficient Steel Warehouse Building Solar Ready Roof 100mm Rock Wool Insulation factory
<
Quality Energy Efficient Steel Warehouse Building Solar Ready Roof 100mm Rock Wool Insulation factory
Quality Energy Efficient Steel Warehouse Building Solar Ready Roof 100mm Rock Wool Insulation factory
>

Energy Efficient Steel Warehouse Building Solar Ready Roof 100mm Rock Wool Insulation

Product Summary

Electricity and heat are now a larger lifetime cost than the steel frame in most warehouses. A roof built for future photovoltaic load costs a few percent more at the start and removes the need for a structural retrofit later, while insulation pays back through reduced cooling load in the first two ...

Product Custom Attributes

Roof Solar Allowance::
0.35 KN Per Square Metre Additional Dead Load
Purlin Spacing::
1.2 M In Array Zone, 1.5 M Elsewhere
Wall Insulation::
100 Mm Rock Wool Sandwich Panel
Roof Insulation::
150 Mm Rock Wool With Vapour Control Layer
Daylight Area::
10 Percent Of Roof Area In Translucent Panel
Lighting::
LED High Bay At 100 Lumens Per Watt With Occupancy Sensors
Surface Protection::
Hot Dip Galvanized Secondary Steel, Factory Coated Primary
Span And Height::
30 M Clear Span, 8 M Eave Height
Compliance Basis::
Roof Loads To GB 50009, Structure To GB 50017
Highlight::

energy efficient steel warehouse

,

solar ready warehouse roof

,

insulated steel storage building

Basic Properties

Place of Origin:
China
Brand Name:
KXD Steel Structure
Certification:
ISO 9001, CE, EN 1090
Model Number:
KXD-WH-EE36

Trading Properties

Minimum Order Quantity:
300 square meters
Price:
USD 38 - 65 per square meter
Packaging Details:
Naked bundles in containers, panels edge stacked, accessories crated by installation sequence
Delivery Time:
25 - 35 working days after drawing approval
Payment Terms:
T/T 30% deposit, 70% before shipment; L/C at sight
Supply Ability:
8000 tons per month

Product Description

Electricity and heat are now a larger lifetime cost than the steel frame in most warehouses. A roof built for future photovoltaic load costs a few percent more at the start and removes the need for a structural retrofit later, while insulation pays back through reduced cooling load in the first two summers. This energy efficient warehouse is designed with a 0.35 kN per square metre additional roof load for solar arrays, a 100 mm rock wool insulated envelope and 10 percent daylight panels. KXD Steel Structure designs the roof for the panels the client intends to install, not for a promise.

The solar allowance is a structural commitment. Purlin spacing is reduced to 1.2 m in the array zone, and the frame is checked for the additional dead load plus the wind uplift change that a panel array creates at the edges. Cable routes and inverter positions are coordinated with the roof layout so no penetrations are drilled after the membrane is installed. We also specify a standing seam profile in the array zone where the client wants clamp fixed panels without any roof penetration at all, which is the detail that decides whether a roof stays watertight for twenty years.

Insulation performance is measured in the occupied space, not on the datasheet. A 100 mm rock wool wall with sealed joints and a 150 mm roof build up keeps a working warehouse 6 to 9 degrees cooler than an uninsulated metal shed in summer, which directly reduces evaporative cooling demand and improves worker comfort. Ten percent of the roof area is translucent panel for daylight, positioned to avoid glare on workbenches, and LED high bay fittings are specified at 100 lumens per watt with occupancy sensors in low traffic aisles. Metering is installed at the main board so the client can verify savings rather than estimate them.

Lifecycle decisions are cheaper at design stage. Hot dip galvanized secondary steel and a factory applied coating on primary members extend the repaint interval beyond 15 years, and the roof is detailed for safe access with a walkway and anchor points so maintenance does not damage the panels. We provide an energy model summary with the quotation showing estimated annual cooling load, daylight contribution and solar generation for the client's climate zone, which most buyers use to justify the specification internally.

Key Features
  • Solar ready roof structure: 0.35 kN per square metre additional load allowance with purlins at 1.2 m in the array zone
  • Standing seam option: Clamp fixed photovoltaic panels with no roof penetrations
  • 100 mm rock wool walls: Sealed joints and 150 mm roof build up reduce cooling load significantly
  • Ten percent daylight roof: Translucent panels positioned to avoid glare on work areas
  • LED and occupancy control: High bay fittings with sensors in low traffic aisles
  • Verified savings: Main board metering so the client can measure actual consumption reduction
Technical Specifications
ParameterSpecification
Roof solar allowance0.35 kN per square metre additional dead load
Purlin spacing1.2 m in array zone, 1.5 m elsewhere
Wall insulation100 mm rock wool sandwich panel
Roof insulation150 mm rock wool with vapour control layer
Daylight area10 percent of roof area in translucent panel
LightingLED high bay at 100 lumens per watt with occupancy sensors
Surface protectionHot dip galvanized secondary steel, factory coated primary
Span and height30 m clear span, 8 m eave height
Compliance basisRoof loads to GB 50009, structure to GB 50017
Applications

Food and beverage plants, pharmaceutical warehouses, electronics assembly, cold chain ante rooms and any operation with high internal heat gain benefit most from this envelope. It also suits owners planning to lease roof area to a solar developer, since the structural allowance and cable routes are already in place. Clients targeting a green building rating use the energy model summary as part of their documentation.

Engineering Notes and Quality Control

Roof performance is verified in two stages. Before cladding, purlin spacing and solar zone markings are checked against the array layout drawing. After completion, a thermal imaging survey of the envelope identifies insulation gaps and joint defects, and an air leakage check is run at the wall to roof junction. Solar mounting points are proof loaded, and the standing seam clamps are pull tested on a sample basis. Metering is commissioned and a baseline week of consumption data is recorded for the client's own comparison.

Packaging, Loading and Warranty

Insulated panels ship with edge protection and joint sealant boxed by elevation, solar zone purlins are marked separately so the array area is not confused during erection, and translucent panels are crated to prevent scratching. Documentation includes the array layout drawing, the structural load summary and the energy model output. Structural warranty is 10 years, panel warranty 10 years and coating warranty 15 years. Share your climate data, intended array capacity and internal heat load for a specification with a payback estimate.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.