logo
Quality Fire Rated Steel Structure Manufacturing Plant Building 2 Hour Fire Resistance Industrial Factory Workshop With factory
<
Quality Fire Rated Steel Structure Manufacturing Plant Building 2 Hour Fire Resistance Industrial Factory Workshop With factory
Quality Fire Rated Steel Structure Manufacturing Plant Building 2 Hour Fire Resistance Industrial Factory Workshop With factory
Quality Fire Rated Steel Structure Manufacturing Plant Building 2 Hour Fire Resistance Industrial Factory Workshop With factory
>

Fire Rated Steel Structure Manufacturing Plant Building 2 Hour Fire Resistance Industrial Factory Workshop With

Product Summary

Fire rated steel structure manufacturing plant with 2-hour fire resistance, integrated sprinkler system, designed for industrial safety compliance in manufacturing, chemical processing, and high-fire-risk production facilities.

Product Custom Attributes

Highlight::

fire rated steel structure manufacturing plant

,

2 hour fire resistance industrial factory

,

sprinkler system integrated steel workshop

Product Description

This fire rated steel structure manufacturing plant building delivers comprehensive passive and active fire protection integrated into the structural steel design to achieve up to 2-hour fire resistance ratings required for industrial facilities, chemical processing plants, and high-fire-risk manufacturing operations. The fire protection strategy combines intumescent coating systems on primary structural steel with compartmentation fire walls, automatic sprinkler systems, and smoke ventilation to provide a complete fire safety solution that protects both structural integrity during a fire event and occupant life safety for safe evacuation.

Intumescent coatings provide a thin-film fire protection solution that expands when exposed to fire, forming an insulating char layer that protects the structural steel from reaching critical temperature. Our specification utilizes solvent-based or water-based intumescent systems applied under factory-controlled conditions with certified dry film thickness measured at multiple points per member, achieving R120 (120-minute) fire resistance per EN 13381-8 or equivalent UL 263 certification. For members where intumescent coatings are not suitable, cementitious spray-applied fireproofing or calcium silicate board encasement systems are specified to achieve the required fire resistance period.

Key Features
  • 2-Hour Intumescent Coating System: Factory-applied intumescent fire protection achieving R120 fire resistance rating per EN 13381-8 testing standard, with DFT verified by coating manufacturer inspection and full traceability of coating batch numbers to certified fire test reports for regulatory authority approval.
  • Fire Compartmentation Design: Structural steel framing for fire-rated compartment walls including 4-hour fire walls separating building areas exceeding code-permitted fire compartment sizes, with structural continuity maintained through fire walls using fire-rated connection details and mineral wool fire stopping at all penetrations.
  • Automatic Sprinkler Integration: Roof structure designed for ESFR or standard response sprinkler system installation with adequate clearance between structural members and sprinkler deflectors, sprinkler main support steel integrated into roof truss design, and access walkways for sprinkler system maintenance incorporated into the roof structure.
  • Smoke and Heat Exhaust Ventilation: Automatic opening roof ventilators with fusible link activation integrated into the roof cladding system at calculated spacing intervals for smoke layer management per NFPA 204 or EN 12101 standards, maintaining tenable conditions for occupant evacuation and firefighting access.
  • Fire-Rated Structural Connections: All beam-to-column and beam-to-beam connections protected to the same fire resistance rating as the connected members through extended intumescent coating coverage at connection zones, with special attention to bolt heads, end plates, and stiffeners that have higher section factors and heat up faster than the parent members.
  • Emergency Egress Design: Structural framing around designated exit access routes and exit discharge doors designed to maintain structural stability for the full fire resistance period, with exit passageways enclosed by fire-rated construction and exit door frames fabricated from steel with specified fire rating.
  • Firefighting Access Provisions: Fire appliance access roads around the building perimeter with designated hardstanding areas, fire brigade inlet breeching connections integrated into the building wall structure, and roof access hatches with fixed ladders for firefighting operations incorporated into the structural design.
Technical Specifications
ParameterSpecification
Fire Resistance (Structure)R120 / 2-Hour Rating
Fire Protection MethodIntumescent Coating, Factory Applied
Fire Wall RatingREI 240 / 4-Hour Compartment Wall
Sprinkler SystemESFR K17 or Standard Response
Smoke VentilationAutomatic Roof Vents, Fusible Link
Steel GradeQ355B / ASTM A572 Grade 50
Span Width18m to 36m
Eave Height6m to 15m
Intumescent Coating DFTPer Manufacturer Engineering Judgement
Surface PrepSA 2.5 Blast + Compatible Primer
CertificationEN 13381-8 / UL 263 / BS 476
Design Life50 Years
Applications

This fire-rated manufacturing plant is purpose-designed for chemical processing and storage facilities, paint and coating manufacturing plants, plastics and polymer production factories, woodworking and furniture manufacturing facilities, paper and printing industry plants, textile manufacturing factories, automotive component production with flammable materials, rubber processing facilities, food processing plants with fire risk from oils and dust, and any industrial manufacturing operation where building codes mandate enhanced fire resistance due to the combustible nature of raw materials, processes, or stored products.

Packaging & Quality Assurance

All fire-protected structural steel is handled with enhanced care protocols to prevent damage to the intumescent coating. Coated members are protected with temporary wrapping during handling and are loaded with padded contact points in transport bundles. Intumescent coating thickness is verified with electronic gauges at multiple points per member before packing, with records included in the project quality dossier. Touch-up kits with compatible intumescent material are provided for field repair of any handling or erection damage. For board-encased members, boards are packed separately in purpose-built crates with edge protection. The complete fire engineering report, coating manufacturer application certificate, and fire test certification documentation are included. We provide technical support for fire authority submissions including structural fire engineering calculations demonstrating compliance with the specified fire resistance period.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.